Power Management System

Power your equipment with full security

banner-saifor-alimentacion-intelegente

Power Distribution Units (PDU´s) are necessary for every installation. Intelligent PDU´s enable controlling and monitoring the equipment´s power supply and diversifying power sources.

check-saifor SENTRY BASIC PDU

check-saiforMETERED CDU
ZERO-U VERTICAL ENCLOSURES
HORIZONAL  RACK MOUNTED ENCLOSURES

check-saiforSmart CDU
ZERO-U VERTICAL ENCLOSURES
SMART MODULAR 3-PHASE ENCLOSURES
HORIZONTAL RACK MOUNTED

check-saiforSWITCHED CDU
ZERO-U VERTICAL ENCLOSURES
HORIZONTAL RACK MOUNTED ENCLOSURES

check-saiforFAIL SAFE TRANSFER SWITCH

check-saiforPOP’S SWITCHED CDU

check-saiforSMART & SWITCHED CDU WITH PIPS

check-saiforMAIN FEATURES
SENTRY SMART LOAD SHEDDING
SENTRY ACCESS
LINKABLE EXPANSION MODULE
SENTRY CDU PRODUCT FAMILY & FEATURES

check-saiforSENTRY POWER MANAGER

check-saiforPOWER CORDS

Sentry basic
PDU

The Sentry Basic CDU products provide reliable power distribution for all the devices in the equipment cabinet, from 2kW-6kW per cabinet.

Metered
CDU

ZERO-U VERTICAL ENCLOSURES

The Sentry Metered CDU products provide reliable power distribution for all devices in the equipment cabinet, from 2kW-22kW per cabinet. Local input current monitoring allows the installation engineer to verify the aggregate load on the circuit or phase.

HORIZONTAL RACK MOUNTED ENCLOSURES

The Sentry Metered CDU products provide reliable power distribution for all devices in the equipment cabinet, from 2kW-22kW per cabinet. Local input current monitoring allows the installation engineer to verify the aggregate load on the circuit or phase.

 

Smart
CDU

ZERO-U VERTICAL ENCLOSURES

The Smart CDU products provide reliable power distribution coupled with remote power and environmental monitoring.

Use the network interface to view power, temperature and humidity levels via Web browser, or SNMP-based and email alerts when conditions exceed defined thresholds.

SMART MODULAR 3-PHASE ENCLOSURES

The Smart CDU products provide reliable power distribution coupled with remote power and environmental monitoring. Use the network interface to view power, temperature and humidity levels via Web browser, or SNMP-based and email alerts when conditions exceed defined thresholds.

HORIZONTAL RACK MOUNTED ENCLOSURES

The Smart CDU products provide reliable power distribution coupled with remote power and environmental monitoring. Use the network interface to view power, temperature and humidity levels via Web browser, or SNMP-based and email alerts when conditions exceed defined thresholds.

Switched CDU

ZERO-U VERTICAL ENCLOSURES

The Switched CDU products provide the capability to securely monitor and control cabinet power via a network for a data center or remote branch office. The Switched CDU’s combine networked configuration and management with power distribution and power and environmental monitoring. Reboot a single or dual power server with one command. Receive SNMP-based or email alerts when power or environmental conditions exceed thresholds. Assign access rights to user groups or individuals.

Switched CDU products provide the flexibility needed for all data centers and remote sites, including power requirements for high-amperage and high-voltage, EN 60950-1:2001 Branch Circuit Protection, and SNMP traps and email alerts including current monitoring.

These products combine networked configuration and management with power distribution and power and environmental monitoring.

HORIZONTAL RACK MOUNTED ENCLOSURES

The Switched CDU products provide the capability to securely monitor and control cabinet power via a network for a data center or remote branch office. The Switched CDU’s combine networked configuration and management with power distribution and power and environmental monitoring. Reboot a single or dual power server with one command. Receive SNMP-based or email alerts when power or environmental conditions exceed thresholds. Assign access rights to user groups or individuals.

Switched CDU products provide the flexibility needed for all data centers and remote sites, including power requirements for high-amperage and high-voltage, EN 60950-1:2001 Branch Circuit Protection, and SNMP traps and email alerts including current monitoring.

Fail Safe Transfer Switch

The Sentry Fail Safe Transfer Switch features two input power feeds, from separate AC circuits, to supply single-power equipment with dual, redundant power sources. With these automatic transfer switches, if either power in-feed becomes unavailable, then the Sentry FSTS auto-switches to the remaining power feed source to reestablish power to the connected equipment.

Pop’s Switched CDU

Sentry POPS (Per Outlet Power Sensing) combines all the features and functions of a Switched CDU with the ability to provide power monitoring per an individual outlet/device. Power information per individual outlet /device includes current, voltage, power (kW), apparent power, crest factor, and power factor. Using our grouping technology, power information is available per device, groups of devices (application), individual CDU or cabinet.

Smart & Switched CDU with pips

Sentry PIPS combines all of the features of a Smart, Switched or POPS CDU with the ability to provide power monitoring per inlet/infeed. Power information per infeed includes current, voltage, power, apparent power, crest factor, reactance, power factor and accumulated energy. The  PIPS CDU is capable of being accessed through either a secure network or serial connection. The secure integral web interface provides a simple and easy way to monitor the CDU. Configuration choices include: SNMP traps, email alerts, grouping, and all security and communication settings.  Research shows that measuring at the infeed level is the most accurate place to measure power and is recommended by the Green Grid.

Smart load shedding

The first one to offer datacenter managers the ability to automatically manage Switched CDU power outlets based on key operating parameters, including temperature, in-feed load, and UPS power status. Each outlet may be controlled by one or more of these parameters. Should the temperature or load current exceed defined thresholds or the UPS lose power and go onto battery, all or a portion of the loads may be automatically shed to ensure longer operational life of your critical devices.

Features

check-saiforEasy to use, integral, web based GUI configuration tool.

check-saifor “Auto-recovery” with a reboot delay time when conditions return to normal levels.

check-saiforEach CDU outlet is assigned the IP address of the connected device for shut down notification.

check-saiforRemote shutdown agent for server shut down.

check-saiforSNMP trap notifications

check-saiforLoad shedding event notifications via SNMP traps or Email alerts

Sentry access

The first one to offer datacenter managers the ability to automatically manage Switched CDU power outlets based on key operating parameters, including temperature, in-feed load, and UPS power status. Each outlet may be controlled by one or more of these parameters.

Should the temperature or load current exceed defined thresholds or the UPS lose power and go onto battery, all or a portion of the loads may be automatically shed to ensure longer operational life of your critical devices.

Features

check-saiforSecure, web based GUI configuration tool.

check-saiforTemperature Support (Celsius/Fahrenheit) and Humidity (%)

check-saiforLogs authentications, configuration changes and system events.

check-saiforSNMP and email notifications for multiple users of log, event, power, and authorization, configuration messages.

check-saiforSYSLOG logging protocol support.

check-saiforAutomatic Firmware Updates via FTP.

check-saiforStrong Password Support and Pre-Login Banner.

POWER INFORMATION

Input feed voltage (VAC)
Input feet watts (W)
System total watts (W)
System footprint (SqFt / sqM)
System watts /area (W/SqFt / W/SqM)

COMMUNICATION TOOLS

Web interface, SSL, SSH, Telnet, SNMP & RS-232 access, 10/100 Base TEthernet, SSLv3/TLSv1, SNMPv2, TACACS+, LDAP, LDAPS, RADIUS, DHCP, SMTP/ Email, and Syslog

LINKABLE EXPANSION MODULE

The Expansion Module CDU, Smart CL, Switched CX or Switched CXG is our exclusive method for linking together outlets on different power circuits.

The Expansion Module increases the number of managed outlets on a single IP address. Each expansion module links to its parent Smart or Switched, which contains both network and serial interfaces. When linked to a Smart or Switched CDU, the outlets are auto-discovered by the CDU’s firmware, and all available outlets are viewable through the firmware. On the Switched POPS, outlets are individually controllable, or groups of outlets can be controlled with the Switched POPS with one command. Each Expansion Module CDU can be a single or dual-power feed and a Zero-U or horizontal enclosure.

SENTRY CDU PRODUCT FAMILY & FEATURES

The Expansion Module CDU, Smart CL or Switched CX, is our exclusive method for linking together outlets on different power circuits. The Expansion Module CDU, CL or CX, increases the number of managed outlets on a single IP address. Each expansion module links to its parent Smart CS or Switched CW, which contains both network and serial interfaces. When linked to a Smart or Switched CDU, the CL’s or CX’s outlets are auto-discovered by the Smart or Switched CDUs firmware, and all available outlets are viewable through the firmware.

Adds Per Outlet Power Sensing (POPS) to the Switched CDU which provides power monitoring per an individual outlet/device.

General features

of family products

check-saifor1. Zero-U button or bracket mounting for mounting vertical CDU’s in the back or on the side of the cabinet to avoid consuming valuable “U” space.

check-saifor2. All Sentry CDU’s meet the EN 60950-1:2001 requirement for branch circuit protection and use either fuses or circuit breakers to protect each branch of outlets.

check-saifor3. The CDU’s exclusive True RMS Current Monitoring is critical to preventing overloads in high-density computing environments. Digital LED displays on the CDU enclosure report the input current of each phase or branch circuit.

check-saifor4. External probes, with 3-meter cable, capable of measuring temperature & humidity. Receive SNMP-based or email alert notifications when conditions exceed defined thresholds.

check-saifor5. Our exclusive method for linking additional outlets, on separate CDU’s, together under a single IP address, and provides support for A & B power in-feeds.

check-saifor6. Web interface, SSL, SSH, Telnet, SNMP and RS-232 access, 10/100 Base T-Ethernet, SSLv3/ TLSv1, SNMPv2, TACACS+, LDAP, LDAPS, RADIUS, DHCP, SMTP/Email, and Syslog.

check-saifor7. Control individual outlets or groups of outlets with ON, OFF and Reboot functionality for networked reboot of unresponsive servers and network equipment.

check-saifor8. Monitor Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor and Power Factor per outlet.

Sentry Power Manager

The Sentry Power Manger (SPM) product is capable of monitoring and managing multiple Sentry devices on IP-based enterprise networks. SPM provides a global view o all Sentry CDU’s along with the ability to view devices based on their temperature, humidity, current and device status.
Besides managing and monitoring all alarm conditions, this information can also be used to provide reporting and trending information.

Features

check-saiforEvent notification.

check-saiforMultiple reporting options.

check-saiforOn-demand accessibility.

check-saiforMultiple Web browsers supported.

check-saiforSQL 2005 databases supported.

check-saiforCompatibility with Sentry CDU firmware 5.3x or later.

Power Cords

Saifor provides 16 and 32A products with a variety of input cord options. Please refer to the Power Cords and cordset options above for different configurations. Shown above are standard power cord and cordset options. Saifor offers a wide range of products for global markets.